ORIGINAL ARTICLE
Year : 2020  |  Volume : 12  |  Issue : 1  |  Page : 47-51

Effect of Different Levels of Salivary pH on the Shear Bond Strength of Two Orthodontic Adhesive Systems for Bracket Placement: An In-vitro Study


1 Division of Orthodontics, School of Dentistry, Universidad Peruana Cayetano Heredia, Lima, Perú
2 Division of Orthodontics, School of Dentistry, Universidad Científica del Sur, Lima, Perú

Correspondence Address:
Angelita Leonarda Carpio Contreras
Division of Orthodontics, Faculty of Dentistry, Universidad Peruana Cayetano Heredia, Lima, Perú. Av. Honorio Delgado 430, San Martin de Porres.

Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jofs.jofs_109_19

Rights and Permissions

Introduction: The aim of this study was to compare the effect of four different salivary pH levels on the shear bond strength (SBS) of two orthodontic adhesive systems for bracket placement. Materials and Methods: This in-vitro experimental study was performed on 72 premolars extracted for orthodontic reasons. They were randomly assigned into two groups according to the adhesive system employed: Orthocem (light-cure adhesive, FGM®) or Transbond-XT (3M Unitek). Each group involved nine specimens incubated in artificial saliva at four pH levels regarding previous studies: acidic pH (4.8 and 5.8), control pH (6.8) and alkaline pH (7.8), during two months. Once removed, shear bond strength with a universal testing machine was applied. The SBS comparisons between adhesive systems was obtained using t-test and for salivary pH levels in each group one-way ANOVA and Tukey tests were used (P < 0.05). Results: Transbond-XT adhesive system showed the greater SBS, mainly in the neutral salivary pH (11.18 ± 2.82 Mpa) followed by the alkaline (10.33 ± 2.49 Mpa) (P > 0.05). Significant differences were found regarding to both acidic pH levels (pH 4.8 and 5.8) with values between 6 and 8 MPa (P < 0.05). Moreover, Orthocem adhesive system had lower SBS values, with greater value in the neutral salivary pH (6.24 Mpa), don’t achieved significant differences with the other pH levels; 4.74 Mpa for pH 4.8 and 5.05 Mpa for pH 5.8. Conclusion: Transbond XT orthodontic adhesive system showed only greater values of SBS only for the control and alkaline pH levels; for acidic pH levels there was no difference between the two systems. This situation must be taken into account by clinicians.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed192    
    Printed12    
    Emailed0    
    PDF Downloaded39    
    Comments [Add]    

Recommend this journal