ORIGINAL ARTICLE
Year : 2020  |  Volume : 12  |  Issue : 2  |  Page : 91-95

Evaluation of the Genotoxic Effects of Orthodontic NiTi Wires on Oral Mucosal Cells: An In Vivo Study


1 Department of Orthodontics and Dentofacial Orthopedics, Yenepoya Dental College and Hospital, Mangalore, Karnataka, India
2 NMC Royal Hospital Dubai, UAE

Correspondence Address:
Dr. Katheesa Parveen
Department of Orthodontics, Yenepoya Dental College, Mangalore, Karnataka, 575018
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jofs.jofs_18_20

Rights and Permissions

Introduction: Orthodontic wires are one of the main components of fixed appliance treatment. Bio-degradation of the metals in these wires could be a source of genotoxicity in the oral cavity. Materials and Methods: After the ethical committee approval and obtaining patient consent, the oral buccal mucosal smears were collected from buccal mucosa using a metal spatula from 27 patients before bonding, during NiTi, and during SS wire stage. The MN assay test was performed using Papanicolaou staining procedure. The micronuclei were examined and counted using previously reported criteria under an electron microscope before bonding, during NiTi, and during SS wire stage. Result: The data collected were subjected to analysis of variance test with Greenhouse–Geisser correction for comparison. It determined that mean mucosa cells differed statistically significantly between time points. Post hoc tests using the Bonferroni correction showed that there was an increase in MN cells from before bonding brackets to the tooth (mean value 6.15 ± 2.769) to during NiTi wire stage (mean value 344.85 ± 64.73), and a reduced count from NiTi wire stage (mean value 344.85 ± 64.73) to SS wire stage (mean value 160.52 ± 47.52). Conclusion: The orthodontic wires were observed to be genotoxic. The NiTi wire is considered to have more potential to cause genotoxicity when compared to SS wires. This could be because of the Ni element present in a higher percentage in NiTi wire as compared to SS wire, hence, element Ni can be considered to be genotoxic. Whether the effect of these wires on oral buccal mucosal cells is reversible has to be evaluated further.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed609    
    Printed18    
    Emailed0    
    PDF Downloaded70    
    Comments [Add]    

Recommend this journal